ICS Advisory (ICSA-21-182-03)

Delta Electronics DOPSoft (Update A)

Click to Tweet.
Click to send to Facebook.
Click to Share.

Legal Notice

All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.


 

1. EXECUTIVE SUMMARY

  • CVSS v3 7.8
  • ATTENTION: Low attack complexity
  • Vendor: Delta Electronics
  • Equipment: DOPSoft
  • Vulnerabilities: Out-of-bounds Read

2. UPDATE INFORMATION

This updated advisory is a follow-up to the original advisory titled ICSA-21-182-03 Delta Electronics DOPSoft that was published July 1, 2021, on the ICS webpage on us-cert.cisa.gov.

3. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow arbitrary code execution and disclose information.

4. TECHNICAL DETAILS

4.1 AFFECTED PRODUCTS

The following versions of DOPSoft, a software supporting the DOP-100 series HMI screens, are affected:

  • DOPSoft Version 4.0.10.17 and prior

4.2 VULNERABILITY OVERVIEW

--------- Begin Update A Part 1 of 2 ---------

4.2.1    OUT-OF-BOUNDS READ CWE-125

The affected product is vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to disclose information.

CVE-2021-27455 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).

--------- End Update A Part 1 of 2 ---------

4.2.2    OUT-OF-BOUNDS READ CWE-125

The affected product is vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.

CVE-2021-27412 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

4.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Taiwan

4.4 RESEARCHER

Natnael Samson (@NattiSamson), working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA.

5. MITIGATIONS

--------- Begin Update A Part 2 of 2 ---------

Delta Electronics will release an updated version of DOPSoft on August 31, 2021, and recommends users install this update on all affected systems.

--------- End Update A Part 2 of 2 ---------

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA also recommends users take the following measures to protect themselves from social engineering attacks:

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.


Contact Information

For any questions related to this report, please contact the CISA at:

Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870

For industrial control systems cybersecurity information:  https://us-cert.cisa.gov/ics 
or incident reporting:  https://us-cert.cisa.gov/report