All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
1. EXECUTIVE SUMMARY
- CVSS v3 7.1
- ATTENTION: Low skill level to exploit
- Vendor: Sensormatic Electronics, LLC, a subsidiary of Johnson Controls
- Equipment: American Dynamics victor Web Client
- Vulnerability: Improper Authorization
2. UPDATE INFORMATION
This updated advisory is a follow-up to the original advisory titled ICSA-20-282-01 Johnson Controls Sensormatic Electronics American Dynamics victor Web Client and Software House C•CURE Web Client that was published October 8, 2020, to the ICS webpage on us-cert.cisa.gov.
3. RISK EVALUATION
Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to delete arbitrary files on the system or render the system unusable through a denial-of-service attack.
4. TECHNICAL DETAILS
4.1 AFFECTED PRODUCTS
Johnson Controls reports that the vulnerability affects the following versions of victor Web Client and C•CURE Web Client software:
- American Dynamics victor Web Client: All versions up to and including v5.4.1
--------- Begin Update A Part 1 of 2 ---------
- Software House C•CURE Web Client: All versions up to and including v2.80
--------- End Update A Part 1 of 2 ---------
4.2 VULNERABILITY OVERVIEW
4.2.1 IMPROPER AUTHORIZATION CWE-285
American Dynamics victor Web Client does not perform an authorization check when an attacker with access from an adjacent network attempts to delete arbitrary files on the system.
CVE-2020-9048 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L).
4.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Ireland
4.4 RESEARCHER
Joachim Kerschbaumer reported this vulnerability to Johnson Controls, Inc.
5. MITIGATIONS
--------- Begin Update A Part 2 of 2 ---------
Johnson Controls recommends users upgrade all versions of victor Web Client to v5.6. Registered users can download the update.
- C•CURE Web v2.60 and earlier -- upgrade to a minimum of v2.70 and install the relevant update below:
- C•CURE Web v2.70 – install the update WebClient_c2.70_5.2_Update02
- C•CURE Web v2.80 – install the update WebClient_c2.80_v5.4.1_Update04
Registered users can obtain the software update by downloading the update.
--------- End Update A Part 2 of 2 ---------
For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2020-09
Further ICS security notices and product security guidance are located at the Johnson Controls product security website.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.
Please share your thoughts.
We recently updated our anonymous product survey; we'd welcome your feedback.