ICS Advisory (ICSA-20-128-01)

Advantech WebAccess Node

Legal Notice

All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.


 

1. EXECUTIVE SUMMARY

  • CVSS v3 9.8
  • ATTENTION: Exploitable remotely/low skill level to exploit
  • Vendor: Advantech
  • Equipment: WebAccess Node
  • Vulnerabilities: Improper Validation of Array Index, Relative Path Traversal, SQL Injection, Stack-based Buffer Overflow, Heap-based Buffer Overflow, Out-of-bounds Read

2. RISK EVALUATION

Successful exploitation of these vulnerabilities may allow information disclosure, remote code execution, and compromise system availability.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of WebAccess Node, an HMI platform, are affected:

  • WebAccess Node Version 8.4.4 and prior
  • WebAccess Node Version 9.0.0

3.2 VULNERABILITY OVERVIEW

3.2.1    IMPROPER VALIDATION OF ARRAY INDEX CWE-129

An improper validation vulnerability exists that could allow an attacker to inject specially crafted input into memory where it can be executed.

CVE-2020-12022 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.2    RELATIVE PATH TRAVERSAL CWE-23

Multiple relative path traversal vulnerabilities exist that may allow an authenticated user to use a specially crafted file to delete files outside the application’s control.

CVE-2020-12010 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:H).

3.2.3    RELATIVE PATH TRAVERSAL CWE-23

Multiple relative path traversal vulnerabilities exist that may allow an attacker to overwrite files outside the application’s control.

CVE-2020-12006 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.4    RELATIVE PATH TRAVERSAL CWE-23

Multiple relative path traversal vulnerabilities exist that may allow a low privilege user to overwrite files outside the application’s control.

CVE-2020-12026 has been assigned to this vulnerability. A CVSS v3 base score of 8.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).

3.2.5    IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND ('SQL INJECTION') CWE-89

Input is not properly sanitized and may allow an attacker to inject SQL commands.

CVE-2020-12014 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.2.6    STACK-BASED BUFFER OVERFLOW CWE-121

Multiple stack-based buffer overflow vulnerabilities exist caused by a lack of proper validation of the length of user-supplied data, which may allow remote code execution.

CVE-2020-12002 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.7    HEAP-BASED BUFFER OVERFLOW CWE-122

Multiple heap-based buffer overflow vulnerabilities exist caused by a lack of proper validation of the length of user-supplied data, which may allow remote code execution.

CVE-2020-10638  has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.8    OUT-OF-BOUNDS READ CWE-125

An out-of-bounds vulnerability exists that may allow access to unauthorized data.

CVE-2020-12018 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Energy, Water and Wastewater Systems
  • COUNTRIES/AREAS DEPLOYED: East Asia, United States, Europe
  • COMPANY HEADQUARTERS LOCATION: Taiwan

3.4 RESEARCHER

Natnael Samson and Z0mb1E, working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA.

4. MITIGATIONS

Advantech has released WebAccessNode Version 8.4.4.P0320844 to address the reported vulnerabilities for users currently using WebAccessNode Version 8.4.4

Advantech has released WebAccessNode Version 9.0.0.P0320900 to address the reported vulnerabilities for users currently using WebAccessNode Version 9.0.0

Note: Upon installation, there is a step to let the user decide whether to define a password code for RPC calls. If the user leaves this blank, the installation will pop up a warning to the user for potential risks that they are willing to take.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:

  • Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
  • When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks: 

No known public exploits specifically target these vulnerabilities.


Contact Information

For any questions related to this report, please contact the CISA at:

Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870

For industrial control systems cybersecurity information:  https://us-cert.cisa.gov/ics 
or incident reporting:  https://us-cert.cisa.gov/report

CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.

This product is provided subject to this Notification and this Privacy & Use policy.

Please share your thoughts.

We recently updated our anonymous product survey; we'd welcome your feedback.