Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low skill level to exploit
- Vendor: Honeywell
- Equipment: MAXPRO VMS & NVR
- Vulnerabilities: Deserialization of Untrusted Data, SQL Injection
2. RISK EVALUATION
Successful exploitation of these vulnerabilities could result in elevation of privileges, cause a denial-of-service condition, or allow unauthenticated remote code execution.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of MAXPRO VMS and NVR, video management systems, are affected:
MAXPRO VMS:
- HNMSWVMS prior to Version VMS560 Build 595 T2-Patch
- HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch
MAXPRO NVR:
- MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch
- MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch
- MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch
- MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch
3.2 VULNERABILITY OVERVIEW
3.2.1 DESERIALIZATION OF UNTRUSTED DATA CWE-502
The affected products are vulnerable to an unsafe deserialization of untrusted data. An attacker may be able to remotely modify deserialized data without authentication using a specially crafted web request, resulting in remote code execution.
CVE-2020-6959 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
3.2.2 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND CWE-89
A SQL injection vulnerability exists that could give an attacker remote unauthenticated access to the web user interface with administrator-level privileges.
CVE-2020-6960 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER
Joachim Kerschbaumer discovered these vulnerabilities; Honeywell reported these vulnerabilities to CISA.
4. MITIGATIONS
Honeywell recommends users update VMS 560 Build 595 T2-Patch for affected VMS systems, and NVR 5.6 Build 595 T2-Patch for affected NVR systems. The updates can be found at the Honeywell’s MyWebTech site via a user account.
Additionally, Honeywell recommends that users:
- Update MAXPRO VMS and NVR to latest R560 and 5.6 before applying this patch.
- Update software patch as recommended in Honeywell security notification (SN 2019-10-25 01).
- As a best practice, Honeywell recommends users isolate their systems from the Internet or create additional layers of defense by placing the affected hardware behind a firewall or into a DMZ; and if remote connections to the network are required, consider using a VPN or other means to ensure secure remote connections into the network where the device is located.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
No known public exploits specifically target these vulnerabilities.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.