All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.


 

1. EXECUTIVE SUMMARY

  • CVSS v3 7.3
  • ATTENTION: Low skill level to exploit
  • Vendor: Thales DIS
  • Equipment: SafeNet Sentinel LDK License Manager Runtime
  • Vulnerability: Link Following

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow a local attacker to escalate privileges.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of SafeNet Sentinel LDK License Manager, are affected: 

  • SafeNet Sentinel LDK License Manager, all versions prior to 7.101(only Microsoft Windows versions are affected) 

3.2 VULNERABILITY OVERVIEW

3.2.1    IMPROPER LINK RESOLUTION BEFORE FILE ACCESS ('LINK FOLLOWING') CWE-59

The affected product is vulnerable when configured as a service. This vulnerability may allow an attacker with local access to create, write, and/or delete files in system folder using symbolic links, leading to a privilege escalation. This vulnerability could also be used by an attacker to execute a malicious DLL, which could impact the integrity and availability of the system. 

CVE-2019-18232 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Multiple 
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: France

3.4 RESEARCHER

Ryan Wincey of Blizzard Entertainment Red team reported this vulnerability to Thales.

4. MITIGATIONS

Thales recommends upgrading to Version 7.101 or later

For more information see Thales DIS security announcement (login required). 

CISA recommends users take the following measures to protect themselves from social engineering attacks: 

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.


Contact Information

For any questions related to this report, please contact the CISA at:

Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870

For industrial control systems cybersecurity information:  https://us-cert.cisa.gov/ics 
or incident reporting:  https://us-cert.cisa.gov/report

CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.

This product is provided subject to this Notification and this Privacy & Use policy.

Please share your thoughts.

We recently updated our anonymous product survey; we'd welcome your feedback.