ICS Advisory (ICSA-19-304-02)

Honeywell equIP Series IP Cameras

Click to Tweet.
Click to send to Facebook.
Click to Share.

Legal Notice

All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.


 

1. EXECUTIVE SUMMARY

  • CVSS v3 7.5
  • ATTENTION: Exploitable remotely/low skill level to exploit
  • Vendor: Honeywell 
  • Equipment: equIP series IP cameras
  • Vulnerability: Improper Input Validation

2. RISK EVALUATION

Successful exploitation of this vulnerability could result in denial-of-service conditions. 

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Honeywell reports the vulnerability affects the equIP series IP camera products listed fully in the following Honeywell security notification: 

  • Security Notification SN 2019-09-13 01 

This notification can be found at the following location:

https://www.security.honeywell.com/resources/eol-and-security-notices

3.2 VULNERABILITY OVERVIEW

3.2.1    IMPROPER INPUT VALIDATION CWE-20 

A vulnerability exists in the affected products where a specially crafted HTTP packet request could result in a denial of service.

CVE-2019-18228 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy, Healthcare and Public Health
  • COUNTRIES/AREAS DEPLOYED: Worldwide 
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Honeywell reported this vulnerability to CISA.

4. MITIGATIONS

Honeywell has released firmware update packages for all affected products listed above. The package can be downloaded from:

https://mywebtech.honeywell.com/Home

Honeywell recommends that users with potentially affected products take the following steps to protect themselves:

  • Update firmware of vulnerable devices per this security notification;
  • Isolate their system from the Internet or create additional layers of defense to their system from the Internet by placing the affected hardware behind a firewall or into a DMZ; and
  • If remote connections to the network are required, consider using a VPN or other means to ensure secure remote connections into the network where the device is located.

More information on this issue can be found in Honeywell Security Notification SN 2019-09-13 01

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target this vulnerability. 


Contact Information

For any questions related to this report, please contact the CISA at:

Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870

For industrial control systems cybersecurity information:  https://us-cert.cisa.gov/ics 
or incident reporting:  https://us-cert.cisa.gov/report