Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
1. EXECUTIVE SUMMARY
- CVSS v3 5.3
- ATTENTION: Exploitable remotely/low skill level to exploit
- Vendor: Honeywell
- Equipment: Performance IP Cameras and Performance NVRs
- Vulnerability: Information Exposure
2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to view device configuration information.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of Honeywell Performance IP Series cameras and Performance Series NVRs are affected:
Performance IP Series cameras:
- HBD3PR2
- H4D3PRV3
- HED3PR3
- H4D3PRV2
- HBD3PR1
- H4W8PR2
- HBW8PR2
- H2W2PC1M
- H2W4PER3
- H2W2PER3
- HEW2PER3
- HEW4PER3B
- HBW2PER1
- HEW4PER2
- HEW4PER2B
- HEW2PER2
- H4W2PER2
- HBW2PER2
- H4W2PER3
- HPW2P1
Performance Series NVRs:
- HEN08104
- HEN08144
- HEN081124
- HEN16104
- HEN16144
- HEN16184
- HEN16204
- HEN162244
- HEN16284
- HEN16304
- HEN16384
- HEN32104
- HEN321124
- HEN32204
- HEN32284
- HEN322164
- HEN32304
- HEN32384
- HEN323164
- HEN64204
- HEN64304
- HEN643164
- HEN643324
- HEN643484
- HEN04103
- HEN04113
- HEN04123
- HEN08103
- HEN08113
- HEN08123
- HEN08143
- HEN16103
- HEN16123
- HEN16143
- HEN16163
- HEN04103L
- HEN08103L
- HEN16103L
- HEN32103L
3.2 VULNERABILITY OVERVIEW
2.2.1 INFORMATION EXPOSURE CWE-200
The integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras and NVRs (Network Video Recorders), which can be accessed without authentication over the network.
CVE-2019-13523 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Energy, Healthcare and Public Health
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER
Ismail Bulbil reported this vulnerability to CISA.
4. MITIGATIONS
Honeywell has released firmware update packages for all affected products. The updates can be obtained with a customer account at the following location (login required):
https://mywebtech.honeywell.com/Home
Honeywell also recommends the following mitigating factors that users should take to mitigate this vulnerability:
- Update firmware of vulnerable devices according to affected devices outlined in this advisory.
- Isolate affected systems from the Internet or create additional layers of defense between affected systems and the Internet by placing the affected hardware behind a firewall or into a DMZ.
- If remote connections to the network are required, consider using a VPN or other means to ensure secure remote connections into the network where the device is located.
More information on this issue can be found in Honeywell security notification SN 2019-04-30 01 at the following location on the Honeywell site:
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
No known public exploits specifically target this vulnerability.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.
Please share your thoughts.
We recently updated our anonymous product survey; we'd welcome your feedback.