ICS Advisory (ICSA-19-225-03)

Siemens SCALANCE X Switches (Update B)

Click to Tweet.
Click to send to Facebook.
Click to Share.

Legal Notice

All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.


 

1. EXECUTIVE SUMMARY

  • CVSS v3 8.6
  • ATTENTION: Exploitable remotely/low skill level to exploit
  • Vendor: Siemens
  • Equipment: SCALANCE X switches
  • Vulnerability: Insufficient Resource Pool

2. UPDATE INFORMATION

This updated advisory is a follow-up to the advisory update titled ICSA-19-225-03 Siemens SCALANCE X Switches (Update A) that was published August 20, 2019, on the ICS webpage on us-cert.cisa.gov.

3. RISK EVALUATION

Successful exploitation of this vulnerability could cause a denial-of-service condition.

4. TECHNICAL DETAILS

4.1 AFFECTED PRODUCTS

The following versions of SCALANCE X switches are affected:

--------- Begin Update B Part 1 of 2 ---------

  • SCALANCE X-200 switch family (incl. SIPLUS NET variants): All versions
  • SCALANCE X-200IRT switch family (incl. SIPLUS NET variants): All versions prior to 5.5.0

--------- End Update B Part 1 of 2 ---------

    • SCALANCE X-200RNA: All versions

    4.2 VULNERABILITY OVERVIEW

    4.2.1    INSUFFICIENT RESOURCE POOL CWE-410

    An attacker may send large message packages repeatedly to the telnet service, which may allow a denial-of-service condition.

    CVE-2019-10942 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).

    4.3 BACKGROUND

    • CRITICAL INFRASTRUCTURE SECTORS: Chemical, Critical Manufacturing, Energy, Food and Agriculture, and Water and Wastewater Systems
    • COUNTRIES/AREAS DEPLOYED: Worldwide
    • COMPANY HEADQUARTERS LOCATION: Germany

    4.4 RESEARCHER

    --------- Begin Update B Part 2 of 2 ---------

      Younes Dragoni and Alessandro Di Pinto from Nozomi Networks and Artem Zinenko from Kaspersky reported these vulnerability details to Siemens.

      5. MITIGATIONS

      Siemens has identified the following specific updates, workarounds and mitigations users can apply to reduce the risk:

      --------- End Update B Part 2 of 2 ---------

        • Disable telnet service on affected devices. Users should use SSH instead.
        • Restrict network access to Port 23/TCP of the device.

        Siemens recommends users configure their environment according to Siemens’ operational guidelines for industrial security and follow the recommendations in the product manuals.

        Additional information on industrial security by Siemens can be found at:

        https://www.siemens.com/industrialsecurity

        For more information on the vulnerability and more detailed mitigation instructions, please see Siemens security advisory SSA-100232

        CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:

        CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

        CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

        Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

        Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

        • Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.
        • Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
        • When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.

        CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

        CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

        Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

        Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

        No known public exploits specifically target this vulnerability.


        Contact Information

        For any questions related to this report, please contact the CISA at:

        Email: CISAservicedesk@cisa.dhs.gov
        Toll Free: 1-888-282-0870

        For industrial control systems cybersecurity information:  https://us-cert.cisa.gov/ics 
        or incident reporting:  https://us-cert.cisa.gov/report

        CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.

        This product is provided subject to this Notification and this Privacy & Use policy.

        Please share your thoughts.

        We recently updated our anonymous product survey; we'd welcome your feedback.