ICS Advisory (ICSA-19-164-01)

Johnson Controls exacqVision Enterprise System Manager

Legal Notice

All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.


 

1. EXECUTIVE SUMMARY

  • CVSS v3 6.7
  • Vendor: Johnson Controls
  • Equipment: exacqVision Enterprise System Manager (ESM)
  • Vulnerability: Improper Authorization

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow malicious code execution.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

This vulnerability impacts exacqVision ESM v5.12.2 and prior. All Microsoft Windows operating systems are affected with the exception of Microsoft Windows Server.

3.2 VULNERABILITY OVERVIEW

3.2.1    IMPROPER AUTHORIZATION CWE-285

By default, excessive permissions to directories are granted to authorized, low-privilege system accounts. This could be leveraged by an attacker to make application file changes or to enable privilege escalation attacks.

CVE-2019-7588 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Ireland

3.4 RESEARCHER

@bzyo_ reported this vulnerability to Johnson Controls. Johnson Controls reported this vulnerability to NCCIC.

4. MITIGATIONS

Johnson Controls recommends the following:

For questions concerning this product, contact Johnson Controls Global Product Security:

https://www.johnsoncontrols.com/cyber-solutions
productsecurity@jci.com

NCCIC recommends users take the following measures to protect themselves from social engineering attacks:

NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.

No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. High skill level is needed to exploit.


Contact Information

For any questions related to this report, please contact the CISA at:

Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870

For industrial control systems cybersecurity information:  https://us-cert.cisa.gov/ics 
or incident reporting:  https://us-cert.cisa.gov/report

CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.

This product is provided subject to this Notification and this Privacy & Use policy.

Please share your thoughts.

We recently updated our anonymous product survey; we'd welcome your feedback.