ICS Advisory (ICSA-19-073-01)

LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA ELS Files

Legal Notice

All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.


 

1. EXECUTIVE SUMMARY

  • CVSS v3 7.8
  • ATTENTION: Low skill level to exploit
  • Vendor: LCDS—Leão Consultoria e Desenvolvimento de Sistemas LTDA ME
  • Equipment: LAquis SCADA
  • Vulnerability: Out-of-Bounds Write

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow remote code execution.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following version of LAquis SCADA, an industrial automation software, is affected:

  • SCADA 4.1.0.4150

3.2 VULNERABILITY OVERVIEW

3.2.1    OUT-OF-BOUNDS WRITE CWE-787

Opening specially crafted ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process.

CVE-2019-6536 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Chemical, Commercial Facilities, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater Systems
  • COUNTRIES/AREAS DEPLOYED: South America
  • COMPANY HEADQUARTERS LOCATION: Brazil

3.4 RESEARCHER

Mat Powell, working with Zero Day Initiative, reported this vulnerability to NCCIC.

4. MITIGATIONS

LCDS recommends users update to Version 4.3.1.71, which can be found at the following location:

https://laquisscada.com

NCCIC recommends that users take the following measures to protect themselves from social engineering attacks: 

NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.

This vulnerability is exploitable locally. No known public exploits specifically target this vulnerability.


Contact Information

For any questions related to this report, please contact the CISA at:

Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870

For industrial control systems cybersecurity information:  https://us-cert.cisa.gov/ics 
or incident reporting:  https://us-cert.cisa.gov/report