All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
1. EXECUTIVE SUMMARY
- CVSS v3 4.0
- ATTENTION: Low skill level to exploit
- Vendor: Siemens
- Equipment: SIMATIC STEP 7 (TIA Portal)
- Vulnerability: Unprotected Storage of Credentials
2. RISK EVALUATION
Successful exploitation of this vulnerability could allow an attacker to reconstruct passwords.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
Siemens reports the following SIMATIC STEP 7 product is affected:
- SIMATIC STEP 7 (TIA Portal): All versions prior to 15.1
3.2 VULNERABILITY OVERVIEW
3.2.1 UNPROTECTED STORAGE OF CREDENTIALS CWE-256
Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. This vulnerability could allow the attacker to obtain certain passwords from the project.
CVE-2018-13811 has been assigned to this vulnerability. A CVSS v3 base score of 4.0 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems.
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER
Siemens reported this vulnerability to NCCIC.
4. MITIGATIONS
Siemens recommends users update to Version 15.1, which can be located here:
https://support.industry.siemens.com/cs/us/en/view/109758794
Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:
- Restrict network access to the engineering station and project storage to trusted sources.
- Restrict access to project files on the engineering station and project storage to trusted users.
As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security (https://www.siemens.com/cert/operational-guidelines-industrial-security), and following the recommendations in the product manuals.
Additional information on industrial security by Siemens can be found at:
https://www.siemens.com/industrialsecurity
For more information on this vulnerability and associated software updates, please see Siemens security advisory SSA-621493 on their website:
https://www.siemens.com/cert/advisories
NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.
Please share your thoughts.
We recently updated our anonymous product survey; we'd welcome your feedback.