ICS Advisory (ICSA-17-320-01)

Moxa NPort 5110, 5130, and 5150

Legal Notice

All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.


 

CVSS v3 8.6

ATTENTION: Remotely exploitable/low skill level to exploit.

Vendor: Moxa

Equipment: NPort 5110, 5130, 5150

Vulnerabilities: Injection, Information Exposure, Resource Exhaustion

AFFECTED PRODUCTS

The following versions of NPort, a serial network interface, are affected:

  • NPort 5110 Version 2.2,
  • NPort 5110 Version 2.4,
  • NPort 5110 Version 2.6,
  • NPort 5110 Version 2.7,
  • NPort 5130 Version 3.7 and prior, and
  • NPort 5150 Version 3.7 and prior.

IMPACT

Successful exploitation of these vulnerabilities could allow for remote code execution on the device.

MITIGATION

Moxa has produced new firmware for the affected devices that can be downloaded from:

NPort 5110 https://www.moxa.com/support/download.aspx?type=support&id=882

NPort 5130 and NPort 5150 https://www.moxa.com/support/download.aspx?type=support&id=356

NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:

  • Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
  • When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.

ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.

No known public exploits specifically target these vulnerabilities.

VULNERABILITY OVERVIEW

An attacker may be able to inject packets that could potentially disrupt the availability of the device.

CVE-2017-16719 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

An attacker may be able to exploit a flaw in the handling of Ethernet frame padding that may allow for information exposure.

CVE-2017-16715 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L).

An attacker may be able to exhaust memory resources by sending a large amount of TCP SYN packets.

CVE-2017-14028 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

RESEARCHER

Florian Adamsky reported the vulnerabilities to ICS-CERT and tested the new firmware.

BACKGROUND

Critical Infrastructure Sectors: Critical Manufacturing, Energy, and Transportation Systems

Countries/Areas Deployed: Worldwide

Company Headquarters Location: Taiwan


Contact Information

For any questions related to this report, please contact the CISA at:

Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870

For industrial control systems cybersecurity information:  https://us-cert.cisa.gov/ics 
or incident reporting:  https://us-cert.cisa.gov/report

CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.

This product is provided subject to this Notification and this Privacy & Use policy.

Please share your thoughts.

We recently updated our anonymous product survey; we'd welcome your feedback.