Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
1. EXECUTIVE SUMMARY
- CVSS v3 8.2
- ATTENTION: Exploitable remotely/low skill level to exploit
- Vendor: Siemens
- Equipment: SIMATIC
- Vulnerabilities: Improper restriction of XML external entity reference
2.
UPDATE INFORMATIONThis updated advisory is a follow-up to the original advisory titled ICSA-17-243-01 Siemens OPC UA Protocol Stack Discovery Service (Update C) that was published February 5, 2019, on the ICS webpage on us-cert.gov.
3. RISK EVALUATION
Successful exploitation of this vulnerability may allow an attacker to access various resources.
4. TECHNICAL DETAILS
4.1 AFFECTED PRODUCTS
Siemens reports that the vulnerability affects the following industrial products, which use the Discovery Service of the OPC UA protocol stack by the OPC foundation:
- SIMATIC IT Production Suite: Versions between v6.5 and v7.1
--------- Begin Update D Part 1 of 2 ---------
- SIMATIC NET PC Software: v14 and prior and versions prior to v15
--------- End Update D Part 1 of 2 ---------
4.2 VULNERABILITY OVERVIEW
4.2.1 IMPROPER RESTRICTION OF XML EXTERNAL ENTITY REFERENCE ('XXE') CWE-611
By sending specially crafted packets to the OPC Discovery Server at Port 4840/TCP, an attacker may be able to cause the system to access various resources chosen by the attacker.
CVE-2017-12069 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H).
4.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Chemical, Energy, Food and Agriculture, Water and Wastewater Systems
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Germany
4.4 RESEARCHER
Sergey Temnikov of Kaspersky Lab reported this vulnerability to Siemens.
5. MITIGATIONS
Siemens provides fixes for the following products and recommends users upgrade to the newest version:
- SIMATIC IT Production Suite:
Contact local support to update to v7.1
- SIMATIC NET PC Software: Update to Version 15 or later
- SIMATIC WinCC Runtime Professional: Update to v14 SP1
Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk:
- Operating the devices only within trusted networks.
- Turn off the discovery service after commissioning or block it on the local firewall,
- Apply cell protection concept,
- Use VPN for protecting network communication between cells, and
- Apply defense in depth.
Siemens recommends users protect network access with appropriate mechanisms such as firewalls, segmentation, and VPNs. Siemens also advises that users configure the operational environment according to Siemens Operational Guidelines for Industrial Security.
For more information on this vulnerability and more detailed mitigation instructions, please see Siemens Security Advisory SSA-535640.
The OPC Foundation also published a security bulletin for this vulnerability.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
No known public exploits specifically target this vulnerability.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.
Please share your thoughts.
We recently updated our anonymous product survey; we'd welcome your feedback.