All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
OVERVIEW
Siemens reports that there is a vulnerability in Siemens-branded IP cameras from Vanderbilt Industries. Vanderbilt has released updates to mitigate this vulnerability.
This vulnerability could be exploited remotely.
AFFECTED PRODUCTS
Siemens reports that the vulnerability affects the following versions of Siemens-branded IP cameras built by Vanderbilt Industries:
- CCMW3025: All versions prior to 1.41_SP18_S1,
- CVMW3025-IR: All versions prior to 1.41_SP18_S1,
- CFMW3025: All versions prior to 1.41_SP18_S1,
- CCPW3025: All versions prior to 0.1.73_S1,
- CCPW5025: All versions prior to 0.1.73_S1,
- CCMD3025-DN18: All versions prior to v1.394_S1,
- CCID1445-DN18: All versions prior to v2635,
- CCID1445-DN28: All versions prior to v2635,
- CCID1445-DN36: All versions prior to v2635,
- CFIS1425: All versions prior to v2635,
- CCIS1425: All versions prior to v2635,
- CFMS2025: All versions prior to v2635,
- CCMS2025: All versions prior to v2635,
- CVMS2025-IR: All versions prior to v2635,
- CFMW1025: All versions prior to v2635, and
- CCMW1025: All versions prior to v2635.
IMPACT
A successful exploit of this vulnerability may allow the attacker to obtain administrative credentials.
Impact to individual organizations depends on many factors that are unique to each organization. NCCIC/ICS-CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation.
BACKGROUND
Vanderbilt Industries acquired the SIEMENS IP Cameras business in June 2015 and released updates for the affected camera models under the SIEMENS brand.
The SIEMENS-branded IP-based CCTV cameras portfolio includes a range of megapixel cameras in various configuration and mounting options. According to Vanderbilt, these products are deployed across several sectors including Commercial Facilities, Healthcare and Public Health, and Government Facilities. Vanderbilt estimates that these products are used worldwide.
VULNERABILITY CHARACTERIZATION
VULNERABILITY OVERVIEW
INSUFFICIENTLY PROTECTED CREDENTIALSa
An attacker with network access to the web server could obtain administrative credentials by sending certain requests.
CVE-2016-9155b has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).c
VULNERABILITY DETAILS
EXPLOITABILITY
This vulnerability could be exploited remotely.
EXISTENCE OF EXPLOIT
No known public exploits specifically target this vulnerability.
DIFFICULTY
An attacker with a low skill would be able to exploit this vulnerability.
MITIGATION
Vanderbilt has released updates to mitigate this vulnerability. For links to the new versions for each of the affected models, please see Siemens Security Advisory SSA-284765 at the following location:
http://www.siemens.com/cert/advisories
Siemens recommends that users operate the devices within trusted networks and protect network access to the devices with appropriate mechanisms. Siemens also recommends enabling authentication on the web server.
ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.
- a. CWE-522: Insufficiently Protected Credentials, https://cwe.mitre.org/data/definitions/522.html, web site last accessed November 17, 2016.
- b. NVD, https://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-9155, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory.
- c. CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, web site last accessed November 17, 2016.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.
Please share your thoughts.
We recently updated our anonymous product survey; we'd welcome your feedback.