Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
OVERVIEW
Researcher Jared Bird of Allina Health reported multiple vulnerabilities in the AMTELCO miSecureMessage (MSM) medical messaging system. AMTELCO has an update available to all customers that mitigates the vulnerabilities. The vulnerabilities were discovered during cooperative testing between Allina Health and AMTELCO. This issue was separately reported to CERT/CC, which posted a notification on April 11, 2014, available here:
http://www.kb.cert.org/vuls/id/251628
These vulnerabilities can be exploited remotely. Exploits that target these vulnerabilities are known to be publicly available.
AFFECTED PRODUCTS
The following AMTELCO products are affected:
- miSecureMessages, Version 6.2 (to include Android, iPhone, and Blackberry mobile device applications).
IMPACT
The MSMs Release 6.2 web service may be susceptible to intrusion, allowing an intruder to receive messages intended for MSM users.
Impact to individual organizations and users depends on many factors that are unique to each organization and user. NCCIC/ICS-CERT recommends that organizations and users evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation.
BACKGROUND
AMTELCO is a US-based company that provides call center communication systems and software applications for call centers, contact centers, healthcare facilities, higher education facilities, executive suites, and developers. In addition to call center systems, AMTELCO offers web-based hosted services and other wireless applications.
The affected products, MSMs, is a HIPAA-compliant, cloud-based messaging and notification application for doctors and hospitals to communicate securely with patients over cellphone and Wi-Fi. AMTELCO products are used in the United States and in more than 20 foreign countries.
VULNERABILITY CHARACTERIZATION
VULNERABILITY OVERVIEW
INFORMATION EXPOSUREa
MSM does not have sufficient session management to prevent modification of message requests. This could allow a valid user to retrieve sensitive message contents and exposing personally identifiable information of other users.
CVE-2014-2347b has been assigned to this vulnerability. A CVSS v2 base score of 7 has been assigned; the CVSS vector string is (AV:N/AC:M/Au:S/C:C/I:P/A:N).c
AUTHENTICATIONd
MSM does not contain sufficient authentication complexity that may allow an attacker to receive message traffic between healthcare providers and patients, potentially exposing personally identifiable information.
CVE-2014-0357e has been assigned to this vulnerability. A CVSS v2 base score of 7 has been assigned; the CVSS vector string is (AV:N/AC:M/Au:S/C:C/I:P/A:N).f
VULNERABILITY DETAILS
EXPLOITABILITY
These vulnerabilities could be exploited remotely.
EXISTENCE OF EXPLOIT
Exploits that target these vulnerabilities are publicly available.
DIFFICULTY
Crafting a working exploit for these vulnerabilities would need a moderate skill level. An amount of session modification is required to exploit these vulnerabilities. This decreases the likelihood of a successful exploit.
MITIGATION
AMTELCO has developed an update, Version 6.3, that resolves these vulnerabilities.
Schedule an upgrade by emailing or calling AMTELCO’s Field Engineering Department at:
email: service@amtelco.com
phone: 1-800-553-7679
Link to the Security Advisory (registration required):
https://service.amtelco.com/INFINITY/MSM/MSM6.2SecurityBriefing.pdf
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents. Individuals should report any malicious activity to their healthcare provider.
In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:
- Do not click web links or open unsolicited attachments in email messages.
- Refer to Recognizing and Avoiding Email Scamsg for more information on avoiding email scams.
- Refer to Avoiding Social Engineering and Phishing Attacksh for more information on social engineering attacks.
- a. CWE-200: Information Exposure, http://cwe.mitre.org/data/definitions/200.html, web site last accessed May 01, 2014.
- b. NVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2014-2347, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory.
- c. CVSS Calculator, http://nvd.nist.gov/cvss.cfm?version=2&vector=AV:N/AC:M/Au:S/C:C/I:P/A:N, web site last accessed May 01, 2014.
- d. CWE-287: Improper Authentication, http://cwe.mitre.org/data/definitions/287.html, web site last accessed May 01, 2014.
- e. NVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2014-0357, web site last accessed May 01, 2014.
- f. CVSS Calculator, http://nvd.nist.gov/cvss.cfm?version=2&vector=AV:N/AC:M/Au:S/C:C/I:P/A:N, web site last accessed May 01, 2014.
- g. Recognizing and Avoiding Email Scams, http://www.us-cert.gov/reading_room/emailscams_0905.pdf, web site last accessed May 01, 2014.
- h. National Cyber Alert System Cyber Security Tip ST04-014, http://www.us-cert.gov/cas/tips/ST04-014.html, web site last accessed May 01, 2014.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.
Please share your thoughts.
We recently updated our anonymous product survey; we'd welcome your feedback.