All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
OVERVIEW
Siemens has identified a BEAST (Browser Exploit Against SSL/TLS) attack vulnerability in Siemens Ruggedcom WIN products. This vulnerability was originally reported directly to Siemens ProductCERT by Dan Frein and Paul Cotter of West Monroe Partners. Siemens has produced a firmware update that fixes compatibility issues with BEAST mitigations of current browser versions.
This vulnerability could be exploited remotely.
AFFECTED PRODUCTS
The following Siemens Ruggedcom WIN product lines are affected:
- WIN7000: all versions prior to v4.4,
- WIN7200: all versions prior to v4.4,
- WIN5100: all versions prior to v4.4, and
- WIN5200: all versions prior to v4.4.
IMPACT
An attacker who successfully exploits a system using this vulnerability may be able to access the session ID of the user’s current web session. If combined with a social engineering attack, the attacker may be able to read traffic exchanged between the user and the device.
Impact to individual organizations depends on many factors that are unique to each organization. NCCIC/ICS-CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation.
BACKGROUND
Siemens is a multinational company headquartered in Munich, Germany.
The Ruggedcom WIN product line is a family of products compliant with the WiMAX 802.16e Wave 2 mobile broadband wireless standard. The product family includes a variety of base stations and subscriber stations. Siemens estimates that these products are used primarily in the United States and Europe with a small percentage in Asia.
VULNERABILITY CHARACTERIZATION
VULNERABILITY OVERVIEW
IMPROPER INPUT VALIDATIONa
The SSL/TLS secured web interface of the affected products is vulnerable to the BEAST attack. As it uses SSL libraries, which are not compatible with 1/n-1 record splitting, some newer browser versions are not able to connect to the web interface.
CVE-2011-3389b has been assigned to this vulnerability. A CVSS v2 base score of 4.3 has been assigned; the CVSS vector string is (AV:N/AC:M/Au:N/C:P/I:N/A:N).c
VULNERABILITY DETAILS
EXPLOITABILITY
This vulnerability could be exploited remotely.
EXISTENCE OF EXPLOIT
No known public exploits specifically target this vulnerability.
DIFFICULTY
An attacker with a moderate skill would be able to exploit this vulnerability.
MITIGATION
Siemens has provided a firmware update (Ruggedcom WIN v4.4) that supports the mitigation technique and recommends customers to update to this version. The update does not fix the BEAST vulnerability itself. After the update, it is possible for customers to securely access the web interface with current version browsers, as the mitigation for the BEAST attack is contained in the browser code.
For more information on this vulnerability and detailed instructions, please see Siemens Security Advisory SSA-353456 at the following location:
http://www.siemens.com/cert/advisories
ICS-CERT encourages asset owners to take additional defensive measures to protect against this and other cybersecurity risks.
- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPN is only as secure as the connected devices.
ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page at: http://ics-cert.us-cert.gov/content/recommended-practices. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Additional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Mitigation Strategies, that is available for download from the ICS-CERT web site (http://ics-cert.us-cert.gov/).
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.
- a. CWE-20: Improper Input Validation, http://cwe.mitre.org/data/definitions/20.html, web site last accessed April 08, 2014.
- b. NVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2011-3389, web site last accessed April 08, 2014.
- c. CVSS Calculator, http://nvd.nist.gov/cvss.cfm?version=2&vector=AV:N/AC:M/Au:N/C:P/I:N/A:N, web site last accessed April 08, 2014.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.
Please share your thoughts.
We recently updated our anonymous product survey; we'd welcome your feedback.