ICS Advisory (ICSA-13-219-01)

Schweitzer Engineering Laboratories Improper Input Validation

Click to Tweet.
Click to send to Facebook.
Click to Share.

Legal Notice

All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.


 

Overview

Adam Crain of Automatak and independent researcher Chris Sistrunk have identified improper DNP3 input validation in Schweitzer Engineering Laboratories’ real-time automation controllers (RTAC). Schweitzer Engineering Laboratories (SEL) has produced updated firmware that mitigates this vulnerability. Adam Crain and Chris Sistrunk tested this version to validate that it resolves the vulnerability. This vulnerability could be exploited remotely.

Affected Products

The following SEL products are affected:

·         SEL-3530-R100 -V0-Z001001-D20090915 through SEL-3530- SEL-3530-R123-V0-Z002001

·         SEL-3530-4-R107-V0-Z001001-D20100818 through SEL-3530-4-R123-V0-Z002001-D20130117

·         SEL-3505-R119-V0-Z001001-D20120720 through SEL-3505-R123-V0-Z002001-D20130117

·         SEL-2241-R113-V0-Z001001-D20110721 through SEL-2241-R123-V0-Z002001-D20130117 

Impact

The RTAC master device can be sent into an infinite loop by sending a specially crafted TCP packet from the master station on an IP-based network. If the device is connected via a serial connection, the same attack can be accomplished with physical access to the master station.  In certain conditions the DNP3 driver will automatically restart and resume communications. Under more severe conditions the device ALARM contact will assert indicating a problem and the device configuration settings must be reloaded.

Impact to individual organizations depends on many factors that are unique to each organization. ICS‑CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation.

Background

SEL is a US-based company that maintains offices in the United States and around the world.

The affected products are RTACs designed for industrial environments. These devices are mostly used in the electric utilities subsector of the energy sector. SEL estimates that these products are used primarily in North America and Europe with a small percentage in Asia.

Vulnerability Characterization

Vulnerability Overview

As this vulnerability affects Internet Protocol-connected and serial-connected devices, two CVSS scores have been calculated.

IMPROPER INPUT VALIDATION - IP-Baseda

The SEL RTAC master does not validate or incorrectly validates input. An attacker could cause the software to go into an infinite loop, causing the process to crash. In certain conditions the DNP3 driver will automatically restart and resume communications.  Under more severe conditions the device ALARM contact will assert indicating a problem and the device configuration settings must be reloaded.

The following scoring is for IP-connected devices.

CVE-2013-2792b  has been assigned to this vulnerability. A CVSS v2 base score of 7.1 has been assigned; the CVSS vector string is (AV:N/AC:M/Au:N/C:N/I:N/A:C).c

IMPROPER INPUT VALIDATION - Serial-Basedd

The SEL RTAC master does not validate or incorrectly validate input. An attacker could cause the software to go into an infinite loop, causing the process to crash. In certain conditions the DNP3 driver will automatically restart and resume communications.  Under more severe conditions the device ALARM contact will assert indicating a problem and the device configuration settings must be reloaded.

The following scoring is for serial-connected devices.

CVE- 2013-2798e  has been assigned to this vulnerability. A CVSS v2 base score of 4.7 has been assigned; the CVSS vector string is (AV:L/AC:M/Au:N/C:N/I:N/A:C)f .

Vulnerability Details

Exploitability

The IP-based vulnerability could be exploited remotely.

The serial-based vulnerability is not remotely exploitable. Local access to the serial-based outstation is required.

Existence of Exploit

No known public exploits specifically target these vulnerabilities.

Difficulty

An attacker with a moderate skill level could craft an IP packet that would be able to exploit this vulnerability for an IP-based device.

An attacker with a high skill level could exploit serial-based vulnerability as physical access to the device or some amount of social engineering is required.

Mitigation

SEL recommends that customers affected by this issue should contact their SEL Sales Representative or Customer Service Representative to obtain a free firmware upgrade CD-ROM packet, including upgrade instructions.

In addition, the researchers suggest the following mitigations:

·         Block DNP3 traffic from traversing onto business or corporate networks through the use of an IPS or firewall with DPN3-specific rule sets.

ICS‑CERT encourages asset owners to take additional defensive measures to protect against this and other cybersecurity risks.

·         Minimize network exposure for all control system devices. Critical devices should not directly face the Internet.

·         Locate control system networks and remote devices behind firewalls, and isolate them from the business network.

·         When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPN is only as secure as the connected devices.

ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT Web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.g  ICS‑CERT reminds organizations to perform proper impact analysis and risk assessment prior to taking defensive measures.

Additional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B—Targeted Cyber Intrusion Detection and Mitigation Strategies,h  that is available for download from the ICS-CERT Web page (http://ics-cert.us-cert.gov/).

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS‑CERT for tracking and correlation against other incidents.


 

 

  • aCWE-20: Improper Input Validation, http://cwe.mitre.org/data/definitions/20.html, Web site last accessed August 06, 2013.
  • bNVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2013-2792, NIST uses this advisory to create the CVE Web site report. This Web site will be active sometime after publication of this advisory.
  • cCVSS Calculator, http://nvd.nist.gov/cvss.cfm?version=2&vector=AV:N/AC:M/Au:N/C:N/I:N/A:C, Web site last accessed August 06, 2013.
  • dCWE-20: Improper Input Validation, http://cwe.mitre.org/data/definitions/20.html, Web site last accessed August 06, 2013.
  • eNVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2013-2798, NIST uses this advisory to create the CVE Web site report. This Web site will be active sometime after publication of this advisory.
  • fCVSS Calculator, http://nvd.nist.gov/cvss.cfm?version=2&vector=AV:L/AC:M/Au:N/C:N/I:N/A:C, Web site last accessed August 06, 2013.
  • gCSSP Recommended Practices, http://ics-cert.us-cert.gov/content/recommended-practices, Web site last accessed August 06, 2013.
  • hTargeted Cyber Intrusion Detection and Mitigation Strategies, http://ics-cert.us-cert.gov/tips/ICS-TIP-12-146-01B, Web site last accessed August 06, 2013.


Contact Information

For any questions related to this report, please contact the CISA at:

Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870

For industrial control systems cybersecurity information:  https://us-cert.cisa.gov/ics 
or incident reporting:  https://us-cert.cisa.gov/report

CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.

This product is provided subject to this Notification and this Privacy & Use policy.

Please share your thoughts.

We recently updated our anonymous product survey; we'd welcome your feedback.