All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
OVERVIEW
This advisory provides mitigation details for vulnerabilities that impact the Siemens COMOS database system.
Siemens has identified a permissions, privileges, and access controls vulnerability in the Siemens COMOS database system. Siemens has produced software updates that mitigate this vulnerability. Siemens has tested the updates to validate that they resolve the vulnerability.
AFFECTED PRODUCTS
The following Siemens COMOS Versions 9.2 and 10.0 are affected:
- COMOS 9.2: all versions < v092_Upd06_Patch010 (9.2.0.6.10) and
- COMOS 10.0: all versions < V100_SP03_Patch004 (10.0.3.0.4)
IMPACT
Successful exploitation of this vulnerability may result in an authenticated user gaining elevated privileges, potentially giving him the ability to modify all COMOS objects available in the database.
Impact to individual organizations depends on many factors that are unique to each organization. ICS‑CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation.
BACKGROUND
Siemens is a multinational company headquartered in Munich, Germany. Siemens develops products mainly in the energy, transportation, and healthcare sectors.
COMOS is an object-oriented database system that supports collecting, processing, saving, and distributing information. COMOS is used across many engineering domains including functional engineering of plans and machines, engineering and design, automation and process control planning, and asset and plant management as examples. COMOS also allows the configuration of user privileges, much like any database system.
VULNERABILITY CHARACTERIZATION
VULNERABILITY OVERVIEW
PERMISSIONS, PRIVILEGES, AND ACCESS CONTROLSa
COMOS authenticated users with read privileges can use the client library to elevate their privileges for the Siemens COMOS database system. This could allow the attacker to access and modify all COMOS objects available in the database.
CVE-2013-3927b has been assigned to this vulnerability. A CVSS v2 base score of 4.6 has been assigned by the vendor; the CVSS vector string is (AV:L/AC:L/Au:N/C:P/I:P/A:P).c
VULNERABILITY DETAILS
EXPLOITABILITY
This vulnerability is not exploitable remotely and cannot be exploited without user interaction. The attacker must have local access to the system as an authenticated Windows user.
EXISTENCE OF EXPLOIT
No known public exploits specifically target this vulnerability.
DIFFICULTY
An attacker with a low skill would be able to exploit this vulnerability.
MITIGATION
Siemens has produced software updates, 9.2.0.6.10 for Version 9.2 and 10.0.3.0.4 for Version 10.0, that resolve this vulnerability. Siemens recommends that asset owners and operators contact Siemens customer support to acquire the software updates.
Siemens contact details for the customer support are available at:
http://support.automation.siemens.com/WW/view/en/16605032
Siemens security advisory is located here:
ICS‑CERT encourages asset owners to take additional defensive measures to protect against this and other cybersecurity risks.
- Minimize network exposure for all control system devices. Critical devices should not directly face the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPN is only as secure as the connected devices.
ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT Web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.d ICS‑CERT reminds organizations to perform proper impact analysis and risk assessment prior to taking defensive measures.
Additional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B—Targeted Cyber Intrusion Detection and Mitigation Strategies,e that is available for download from the ICS-CERT Web page (http://ics-cert.us-cert.gov/).
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS‑CERT for tracking and correlation against other incidents.
- a. CWE-264: Permissions, Privileges, and Access Controls, http://cwe.mitre.org/data/definitions/264.html, Web site last accessed June 18, 2013.
- b. NVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2013-3927 , NIST uses this advisory to create the CVE Web site report. This Web site will be active sometime after publication of this advisory.
- c. CVSS Calculator, http://nvd.nist.gov/cvss.cfm?version=2&vector=%28AV:L/AC:L/Au:N/C:P/I:P/A:P%29, Web site last accessed June 18, 2013.
- d. CSSP Recommended Practices, http://ics-cert.us-cert.gov/content/recommended-practices, Web site last accessed June 18, 2013.
- e. Targeted Cyber Intrusion Detection and Mitigation Strategies, http://ics-cert.us-cert.gov/tips/ICS-TIP-12-146-01B, Web site last accessed June 18, 2013.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.
Please share your thoughts.
We recently updated our anonymous product survey; we'd welcome your feedback.