All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Overview
Independent security researcher Justin W. Clarke of Cylance Inc. has identified a privilege-escalation vulnerability in the GarrettCom Magnum MNS-6K Management Software application via the use of a hard-coded password. This vulnerability could allow a remote attacker with any level of access to the system to escalate the attacker’s privilege to the administrative level. The attacker must have access to a logon account on the device to exploit this vulnerability.
GarrettCom has produced a patch that mitigates this vulnerability.
Affected Products
The following GarrettCom products are affected:
- MNS-6K Rel, v4.1.14, and prior, and
- MNS-6K Rel, v14.1.14 SECURE and prior
Impact
Successful exploitation of this vulnerability from an established account on the system could allow escalation of privileges to full administrative access. The privilege escalation could provide the attacker a vector for making changes to settings, or initiating a complete device shutdown causing a denial of service (DoS).
Impact to individual organizations depends on many factors that are unique to each organization. ICS-CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation.
Background
GarrettCom is a US-based company that maintains offices in the US and Europe. The Magnum MNS-6K Management Software provides device management for the Magnum 6K line of managed Ethernet switches.
Resellers also offer GarrettCom products in South America, China, India, and the Middle East, however, GarrettCom estimates that the affected products are deployed primarily in the United States with a small percentage in Europe and Asia. According to GarrettCom, the 6K line of switches are deployed across several U.S. critical infrastructure sectors including critical manufacturing, defense industrial base, energy, water, and transportation.
Vulnerability Characterization
Vulnerability Overview
Use of Hard-Coded Password1
The Magnum MNS-6K Management Software uses an undocumented hard-coded password that could allow an attacker with access to an established device account to escalate privileges to the administrative or full-access level. While an attacker must use an established account on the device under attack, this vulnerability facilitates the circumvention of physical-connect safeguards and could allow complete administrative level access to the system, compromising system confidentiality, integrity, and availability.
CVE-2012-3014 has been assigned to this vulnerability. A CVSS v2 base score of 7.7 has been assigned; the CVSS vector string is (AV:A/AC:L/Au:S/C:C/I:C/A:C).
Vulnerability Details
Exploitability
An attacker with access to an established user account could remotely log into the affected system and elevate privileges to the administrative level, thereby circumventing the physical-connect safeguards in place for administrative functions.
Existence of Exploit
No known public exploit targets this vulnerability.
Difficulty
An attacker with a low skill could exploit this vulnerability.
Mitigation
Despite this vulnerability not being documented in the May 18, 2012, release notes, GarrettCom has an updated software version that addresses this specific security vulnerability. Release notes and download information can be found at the following URLs:
http://www.garrettcom.com/techsupport/6k_dl/6k440_rn.pdf
http://www.garrettcom.com/techsupport/sw_downloads_6k.htm
ICS-CERT encourages asset owners to take additional defensive measures to protect against this and other cybersecurity risks.
- Remove or change any factory or default accounts on the device.
- Use strong password schemes for logon accounts.
- Minimize network exposure for all control system devices. Critical devices should not directly face the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPN is only as secure as the connected devices.
The Control Systems Security Program (CSSP) also provides a section for control systems security recommended practices on the CSSP Web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to taking defensive measures.
Additional mitigation guidance and recommended practices are publicly available in the ICS-CERT Technical Information Paper, ICS-TIP-12-146-01A—Cyber Intrusion Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.
- 1CWE, http://cwe.mitre.org/data/definitions/259.html , CWE-259: Use of Hard-Coded, Web site last accessed August 30, 2012.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.
Please share your thoughts.
We recently updated our anonymous product survey; we'd welcome your feedback.