All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Overview
This advisory is a follow-up to ICS-ALERT-11-333-01 - MICROSYS PROMOTIC Use-After-Free Vulnerability, released on the ICS-CERT Web site on November 28, 2011.
Independent researcher Luigi Auriemma has identified and released proof of concept code (POC) for a use after free vulnerability in the MICROSYS, spol. s r.o. PROMOTIC application without coordination with ICS-CERT, the vendor, or any other known coordinating entity.
ICS-CERT has coordinated this vulnerability with MICROSYS, which has produced an update that Mr. Auriemma confirms resolves this vulnerability.
Affected Products
The following products are affected:
- PROMOTIC versions prior to Version 8.1.7.
Impact
Successful exploitation of this vulnerability may result in adverse conditions ranging from the corruption of valid data to the execution of arbitrary code.
Impact to individual organizations depends on many factors that are unique to each organization. ICS-CERT recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation.
Background
PROMOTIC is a Microsoft Windows based supervisory control and data acquisition human-machine interface (SCADA HMI) software programming suite for creating applications that monitor, control, and display technological processes.1
MICROSYS, spol. s r.o. is a Czech company with headquarters in Ostrava. The PROMOTIC system is primarily used in Czech and Slovak Republics. It is also used in Poland, Hungary, Slovenia, Serbia, Bulgaria, and Romania.
Vulnerability Characterization
Vulnerability Overview
Use After Freea
A use after free condition can occur when opening a specially crafted project file. Exploitation of this vulnerability may allow data corruption or arbitrary code execution.
CVE-2011-4874b
has been assigned to this vulnerability.
Vulnerability Details
Exploitability
This vulnerability is not remotely exploitable and cannot be exploited without user interaction. The exploit is only triggered when a local user runs the vulnerable application and loads the malformed project file.
Existence of Exploit
Public exploits are known to target this vulnerability.
Difficulty
Crafting a working exploit for this vulnerability would be difficult. Social engineering is required to convince the user to accept the malformed project file. Additional user interaction is needed to load the malformed file. This decreases the likelihood of a successful exploit.
Mitigation
MICROSYS spol. s r.o. recommends that customers with affected versions of PROMOTIC update their installations by downloading the latest version from MICROSYS’ website http://www.promotic.eu/en/firm/microsys.htm.
MICROSYS has produced a news release that contains additional information about these vulnerabilities. http://www.promotic.eu/en/pmdoc/News.htm#ver801057.
ICS-CERT encourages asset owners to take additional defensive measures to protect against this and other cybersecurity risks.
- Minimize network exposure for all control system devices. Critical devices should not directly face the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPN is only as secure as the connected devices.
The Control Systems Security Program (CSSP) also provides a section for control systems security recommended practices on the CSSP web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to taking defensive measures.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.
In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:
- Do not click web links or open unsolicited attachments in e-mail messages.
- Refer to Recognizing and Avoiding Email Scamsc for more information on avoiding e-mail scams.
- Refer to Avoiding Social Engineering and Phishing Attacksd for more information on social engineering attacks.
- 1www.promotic.eu/, website last accessed April 11, 2012.
- ahttp://cwe.mitre.org/data/definitions/416.html, website last accessed April 11, 2012.
- bhttp://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2011-4874 , NIST uses this advisory to create the CVE website report. This website will be active sometime after publication of this advisory.
- cRecognizing and Avoiding Email Scams, http://www.us-cert.gov/reading_room/emailscams_0905.pdf, website last accessed April 11, 2012.
- dNational Cyber Alert System Cyber Security Tip ST04-014, http://www.us-cert.gov/cas/tips/ST04-014.html, website last accessed April 11, 2012.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.
Please share your thoughts.
We recently updated our anonymous product survey; we'd welcome your feedback.