All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Overview
ICS-CERT received a report from GE Intelligent Platforms and the Zero Day Initiative (ZDI) concerning multiple memory corruption vulnerabilities in the GE Intelligent Platforms Proficy Plant Applications. These vulnerabilities were reported to ZDI by independent security researcher Luigi Auriemma.
If exploited, these vulnerabilities could allow an attacker to cause multiple Proficy services to crash, which may lead to arbitrary code execution. concerning multiple memory corruption vulnerabilities in the GE Intelligent Platforms Proficy Plant Applications. These vulnerabilities were reported to ZDI by independent security researcher Luigi Auriemma.
GE Intelligent Platforms has created patches to address these issues.
Affected Products
The following product and versions are affected:
- Proficy Plant Applications: Versions 5.0 and prior.
Impact
Exploitation of these vulnerabilities could cause multiple Proficy services to crash and potentially allow an attacker to take control of a system running the affected software.
Impact to individual organizations depends on many factors that are unique to each organization. ICS-CERT recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation.
Background
According to GE, Proficy Plant Applications suite is an Operations Management software product that is deployed across multiple industries worldwide.
Vulnerability Characterization
Vulnerability Overview
PRRDS.EXE Memory Corruption
Proficy Remote Data Service (PRRDS.exe) listens on Port 12299/TCP by default. CVE-2012-02301 has been assigned to this vulnerability.
PRLICENSEMGR.EXE Memory Corruption
Proficy Server License Manager (PRLicenseMgr.exe) listens on Port 12401/TCP by default. CVE-2012-02312 has been assigned to this vulnerability.
Vulnerability Details
Exploitability
These vulnerabilities are remotely exploitable.
Existence of Exploit
No known public exploits specifically target these vulnerabilities.
Difficulty
An attacker with a moderate skill level would be able to exploit these vulnerabilities.
Mitigation
GE Intelligent Platforms recommends that customers apply product updates to supported Proficy PlantApplications Versions 5.0 and 4.4.1. Proficy Plant Applications customers using unsupported Versions 4.3.1, 4.2.3, 4.2.2, and 215.8 should contact GE Intelligent Platforms Support for assistance with obtaining and applying a patch. GE Intelligent Platforms urges all customers to follow the recommendations in their security advisory.
Note: A valid GE user ID and Customer Service Number are required to access the advisories and updates. Proficy SIMs are cumulative. All future SIMs will include these updates.
ICS-CERT encourages asset owners to take additional defensive measures to protect against this and other cybersecurity risks.
- Minimize network exposure for all control system devices. Critical devices should not directly face the Internet.
- Locate control system networks and remote devices behind firewalls with properly configured rules addressing Port 12299/TCP and Port 12401/TCP, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPN is only as secure as the connected devices.
The Control Systems Security Program (CSSP) also provides a section for control systems security recommended practices on the CSSP web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to taking defensive measures.
In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:
- Do not click web links or open unsolicited attachments in e-mail messages.
- Refer to Recognizing and Avoiding Email Scams for more information on avoiding e-mail scams.
- Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
- 1http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2012-0230, NIST uses this advisory to create the CVE website report. This website will be active sometime after publication of this advisory.
- 2http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2012-0231, NIST uses this advisory to create the CVE website report. This website will be active sometime after publication of this advisory.
Contact Information
For any questions related to this report, please contact the CISA at:
Email: CISAservicedesk@cisa.dhs.gov
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: https://us-cert.cisa.gov/ics
or incident reporting: https://us-cert.cisa.gov/report
CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.
Please share your thoughts.
We recently updated our anonymous product survey; we'd welcome your feedback.